Features
- Solutions from 11 kW to 100 kW
- Peak efficiency (95.6%)
- Fail-safe
- Ease of maintenance
- DC voltage range from 400 V to 900 V
- Intelligent MPP tracking
- Wide operating temperature range: -10°C to +50°C
- Suitable for indoor operation (IP20)
- User-friendly touch-screen display
CI 100 consists of nine high-efficient inverter modules, DC disconnectors, system controllers, and a robust cabinet. Also, if any individual components fail in one of the inverters, a system availability of approximately 90% is guaranteed and the 'redundant system' design of the CI 100 ensures maximum reliability. The concept of the central inverter CI 100 supports the user when expanding the system to increase output etc. and is very easy to service. With the latest high frequency technology, the electrically isolated CI 100 from Delta achieves peak efficiencies up to 95.6%. Highly efficient and reliable, with its intelligent MPP tracking, the central inverter CI 100 gets maximum performance from your solar modules under all operating conditions. Of course, the CI 100 is also fitted with overvoltage protection, heat protection, short-circuit protection and overcurrent protection. Delta's central inverter meets all guidelines regarding safety standards, EMC and national requirements. The user-friendly menu navigation via the integrated touch screen display makes the unit easy to operate. All the operating states and fault messages on the CI 100 or PV installation can be monitored on the illuminated display or invoked via the RS485 interface. You can therefore get an overview of the different measurement values and system data recorded within a day, week, month or year.As with all the solar inverters in the product range from Delta, the CI 100 is compatible with the safer'Sun Monitoring System from Meteocontrol. | Input (DC) | | Output (AC) | | Max. recommended PV power (kW) | 120 | Nominal power (kW) | 100 | | Nominal power (kW) | 105 | Nominal voltage (V) | 3 NPE x 400V, + 15% / -20%* | | Voltage range (V) | 400 ... 900 | Nominal current (A) | 145 per phase | | MPP range (V) | 450 ... 800 | Max. current (A) | 180 | | Full power MPP range (V) | 450 ... 800 | Nominal frequency (Hz) | 50 * | | Max. current (A) | 235 | Frequency range (Hz) | 50 , +/- 2.5 * | | | | | * AC voltage and frequency range will be programmed according to the individual country requirements | | | | | | | General specification | | Mechanical design | | | Max. efficiency (%) | 95.6 | Size (L x W x D ) | 2000 x 1000 x 600 mm³ | Efficiency EU / California (%) | 94.6 | Weight (kg) | 460 | | Operating temperature (°C) | -10 ... +50 | Cooling | Fan cooling | | Storage temperature (°C) | -25 ... +60 | AC connector | Cable end sleeves | | Humidity (%) | 0 ... 95 | DC connector | Tubular cable lugs 3 x M8 | | | | DC disconnect | Integrated | | | | | | | Standards | | Directives | | | Protection class | IP20 | EMC | EN55022 Class B | | Safety class | 1 | | EN61000-4-2 | | Configurable trip parameters | Yes | | EN61000-4-3 | | Insulation monitoring | Yes | | EN610004-4 | | Overload behavior | Current limitation, power limitation | | EN61000-4-5 | | Safety | EN60950-1 | | EN61000-4-6 | | | EN50178 | | EN61000-4-8 | | | Draft IEC62109-1/2 | | EN61000-3-2 | | | IEC 62103 | | | | ENS | DIN VDE 0126-1-1 | | | | | RD 1663; DK 5940 | | | | | | | |
|
|
 |